Vacuum Deaerator for Boiler Feed Water and Heating Systems
Feed Water Vacuum Deaerator
,Stainless Steel Vacuum Deaerator
,OEM deaerator tank in boiler
A vacuum deaerator removes air and dissolved oxygen from liquid products and process water under vacuum. Deaerating the product liquid inhibits browning and the oxidation of pigments, vitamins, and flavor components, removes the micro gas bubbles attached to suspended particles that make them float, prevents foaming during canning and high-temperature sterilization, and reduces corrosion on the inner walls of containers and system components.
In water systems, removing oxygen lowers aerobic corrosion and extends equipment life, and removing gas keeps heat exchanger surfaces free of attached bubbles so that heat transfer efficiency is maintained.
The machine features an adjustable vacuum level with a dedicated vacuum breaking device, an inclined inlet that forms a vortex to improve the deaeration effect, an inclined outlet that keeps the discharge stable under vacuum, and a working time and cycle that can be adjusted to the requirement. Size levels cover processing capacities from 1,000 to 10,000 L/H for reference, and the detailed parameters are confirmed with the buyer according to the process.
Dissolved oxygen in feed water and make-up water attacks the metal of boilers, piping, and hot water systems, and the pitting that follows shortens the service life of the equipment. Removing the oxygen lowers this aerobic corrosion load on the system. In a food factory the same tank serves the utility room as a mechanical deoxygenation stage, arranged before the chemical treatment step of the water program.
Gas dissolved in water comes out of solution on the hot side of a heat exchanger and attaches to the surface as bubbles, where it acts as an insulating film. Removing the gas before the water reaches the exchanger keeps the surfaces free of attached bubbles, so that the heat transfer efficiency of the system is maintained without the film building up over time.
Vacuum deaeration removes oxygen at the temperature of the water itself, which suits systems where thermal deaeration is not practical. The vacuum level is adjustable over approximately -0.098 to -0.08 MPa, the working time and cycle are adjustable to the water demand, and the dedicated vacuum breaking device controls the return to atmosphere. Removal figures depend on the water condition and the operating point, and the expected level for the duty is confirmed with the buyer.
| Item | Specification |
|---|---|
| Processing Capacity | 1,000 / 2,000 / 3,000 / 5,000 / 10,000 L/H by size level |
| Working Pressure | Approximately -0.098 to -0.08 MPa, adjustable |
| Total Motor Power | 4.5 / 4.5 / 5.5 / 7.5 / 7.5 kW by size level |
| Dimensions (L*W*H) | From 1.0*0.75*2.8 m (1,000 L/H) to 1.7*1.8*3.6 m (10,000 L/H) |
| Weight | 220 – 400 kg by size level |
| Vacuum Breaking Device | Dedicated device for controlled vacuum release |
| Feed Design | Inclined inlet forming a vortex to improve the deaeration effect |
| Discharge Design | Inclined outlet for stable discharge under vacuum |
| Working Cycle | Working time and cycle adjustable to the requirement |
| Application Scope | Product liquid deaeration and water system deoxygenation |
For reference only. Detailed parameters, material selection, vacuum pump arrangement, and control configuration depend on the process and are confirmed with the buyer.
- Removing dissolved oxygen lowers the aerobic corrosion load on piping and boilers.
- Gas-free water keeps heat exchanger surfaces free of insulating bubbles.
- The step suits deoxygenation at the working temperature of the system.
- Vacuum level and working cycle are adjustable to the water demand.
- Material and vacuum pump arrangement are confirmed with the buyer.
Factory water systems use vacuum deaeration to remove dissolved oxygen and gas from feed water and circulating water. Dairy and beverage plant utility rooms deaerate boiler feed water and heating make-up water, food plants treat hot water and CIP water systems, regional heating and heat exchange systems run the same step, and beverage plants fit the tank into RO and process water distribution.
Utility upgrade projects, boiler and heating system suppliers, and energy retrofit projects use the deaerator when boiler and hot water piping show oxygen pitting, when heat exchanger performance drops and gas film on the surface is suspected, when make-up water carries high dissolved oxygen and needs a mechanical deoxygenation stage before chemical treatment, or when deoxygenation is needed at ambient temperature and thermal deaeration is not suitable.
Yes. We build equipment to your required output in liters per hour or units per hour.
Yes. We can also send engineers to your site for hands-on installation, commissioning, and operator training.
Yes. We can supply complete turnkey lines including all processing equipment.
Yes. Factory visits are welcome. Our factory is located in Fengxian District, Shanghai, China, a 40-minute drive from Shanghai Pudong International Airport. Please contact us to schedule your visit. Video factory tours are also available for customers who cannot travel.